ASKUE – TEAMI
The ASKUE – TEAMI software is designed for:
- Automating remote data collection from metering devices;
- Storing and analysing consumption;
- Real-time monitoring;
- Flexible report configuration.
Goals of the ASKUE – TEAMI system
- 01Reducing electricity losses
- 02Improving billing and payment collection
- 03Reducing operation and maintenance costs
- 04Improving service quality and the accuracy and quality of electricity metering
- 05Compliance with measures for efficient energy use by end consumers
- 06Collecting information for management operations (planning, tariff design, asset management)
- 07Providing detailed data to improve power generation and balance network load
ASKUE – TEAMI capabilities
Data analysis
Real-time monitoring
Reporting
Flexible system configuration
Control and security
Improved energy efficiency
General functional capabilities of ASKUE
TEAMI advantages
High metering accuracy
Modern technologies
Integration with the ASKUE system
Reliability and durability
An efficient solution for enterprises
Features of ASKUE – TEAMI based on TE71 and TE73 meters
High overall speed of the ASKUE system
State-of-the-art technologies ensure high-quality collection, processing, storage and delivery of information, generation and distribution of reports, notification of dispatchers about tampering with meters and processes in the power system, and control of meter installation, commissioning and verification dates.
No concentrator commissioning required
Lower cost and shorter commissioning time thanks to smart technologies that automate the setup and commissioning of equipment and software.
Automated consumer load management
Automatic tripping of the meters' load control relay by predefined rules in case of subscriber debt, meter tampering or emergency changes in grid parameters.
High scalability and adaptability
- Support for more than 5 million meters;
- Support for metering devices of various utilities: electricity, gas, liquids, heat, etc.;
- Automated generation and distribution of reporting documents;
- Integration with other information systems (billing systems, etc.).
Access from any workstation (WEB server)
- Modern WEB technologies remove the need for mandatory software support on workstations;
- Access to the system is granted strictly according to assigned rights and permissions.
Features of TE71 and TE73 meters
TE71 and TE73 electricity metering devicesReliable solutions for accurate metering and efficient energy resource management
- High measurement accuracy
- Multi-tariff metering
- Reliable data transmission over PLC and other channels
- Compliance with modern requirements
Bidirectional measurement
- Active and reactive energy (import and export), per tariff and total
- Reactive energy in 4 quadrants (for the TE73 M modification)
Accuracy classes
Extended event logs
- Opening of the terminal cover and housing
- Exceeding preset power and voltage thresholds
- Attempts to tamper with the meter
- Attempts to change the meter's connection to the measured network
Various connection schemes
- Direct connection;
- Semi-indirect connection (using CTs);
- Transformer connection (using CTs and VTs): two-element – for the TE73 B modification; three-element – for the TE73 S and TE73 M modifications.
Simultaneous data transfer to several ASKUE systems
Including simultaneous data transfer to the central ASKUE system of the Republic of Uzbekistan (Central AMI System (CAS)) and to commercial ASKUE systems of other vendors (for the TE73 MG modification).



TE71All specifications →
TE73All specifications →